Description
| Input Power | AC380V ±10% / 50Hz | |
| Resolution | AD:16bit;DA:16bit | |
| Input Resistance | ≥1MΩ | |
| Input Power | 7089W | |
| Channel Features | Constant Current Source And Constant Voltage Source With Independent Pairs Of Closed-Loop Structure | |
| Channel Control Mode | Independent Control | |
| Voltage | Constant Voltage Control Range | 0.025V~5V |
| Lowest Discharge Voltage | 2.5V | |
| Accuracy | ± 0.1% Of FS | |
| Stability | ± 0.1% Of FS | |
| Current | Per Channel Output Current Range | 0.5A-100A |
| Cut-Off Current Of CV | 0.2A | |
| Accuracy | ± 0.1% Of FS | |
| Stability | ± 0.1% Of FS | |
| Power | Per Channel Output Power | 500W |
| Stability | ± 0.2% Of FS | |
| Time | Current Response Time | The Current Gets To 10%-90% Of FS Hardware Response Time Is 20ms |
| Step Time Range | Single Step Time Range≤365*24 H,Time Form Support:00:00:00.000(H、Min、S、Ms) | |
| Data Recording | Record Condition | Min Time△T:100ms |
| Min Voltage△U:10mV | ||
| Min Current△I:200mA | ||
| Record Frequency | 10Hz | |
| Charge | Charge Mode | Constant Current Charge、Constant Voltage Charge、Constant Current And Constant Voltage Charge、Constant Power Charge |
| End Conditon | Voltage、Current、Relative Time、Capacity、-△V | |
| Discharge | Discharge Mode | Constant Current Discharge、Constant Power Discharge、Constant Resistance Discharge |
| End Condition | Voltage、Current、Relative Time、Capacity | |
| Pulse | Charge | CCC,CPC |
| Discharge | CCD,CPD | |
| Minimum Pulse Width | 500ms | |
| Pulse | 32 Pulse Setting In One Step | |
| Automated Switch | Automated Switch From Charge To Discharge For Each Pulse | |
| End Condition | Voltage, Test Time | |
| L Setting Protection Condition,Setting Parameter:Low Voltage Limit、Upper | ||
| DCIR | Support DCIR Testing | |
| Parallel | Max 4 Channels Parallel, Don’t Support Pulse Test After Parallel | |
| Cycle | Loop Measure Range | 1~65535 Times |
| Max Steps Per Loop | 254 | |
| Nested Loop | Nested Loop Function,Max Support 3 Layers | |
| Protection | Software Protection | L Power-Down Data Protection |
| L Off-Line Testing Function | ||
| L Setting Protection Condition,Setting Parameter:Low Voltage Limit、Upper Voltage Limit、Low Current Limit、Upper Current Limit、Delay Time | ||
| Hardware Protection | Additional Anti-Reverse Protection Model | |
| Voltage And Current Testing Sample | 4-Wire Connecting | |
| Noise | <85dB | |
| Data Output | EXCEL2003、2010、TXT | |
| Communication Interface | Ethernet Port | |
| Per Unit Main Channels No. | 8 | |